- ImplicitReceive: The input is always buffered. So, the input value remains the same in a single execution of the runnable, no matter how many times it is used.
- ExplicitReceive: The input is not buffered. So, the input value changes whenever it is used within a single execution of the runnable.
What is the difference between ImplicitReceive and ExplicitReceive in AUTOSAR Code?
129 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
MathWorks Support Team
am 14 Aug. 2018
Bearbeitet: MathWorks Support Team
am 28 Jul. 2022
What is the difference when changing DataAccessMode for AUTOSAR inputs between ImplicitReceive and ExplicitReceive?
Akzeptierte Antwort
MathWorks Support Team
am 21 Feb. 2022
Bearbeitet: MathWorks Support Team
am 28 Jul. 2022
In the AUTOSAR sense for the RTE, the main difference is the following:
However, when generating code from Simulink, the code for the explicit case can be seen as buffered in the code, as shown in the examples below:
1) ImplicitReceive
/* Model step function for TID1 */
void Runnable_2s(void) /* Sample time: [2.0s, 0.0s] */
{
/* Update for RateTransition: '<Root>/RateTransition' incorporates:
* DiscreteIntegrator: '<Root>/Integrator'
*/
Rte_IrvIWrite_Runnable_2s_IRV1(rtDW.Integrator_DSTATE);
/* Update for DiscreteIntegrator: '<Root>/Integrator' incorporates:
* Inport: '<Root>/In2_2s'
*/
rtDW.Integrator_DSTATE += 2.0 * Rte_IRead_Runnable_2s_ReceivePort_In2();
}
2) ExplicitReceive
/* Model step function for TID1 */
void Runnable_2s(void) /* Sample time: [2.0s, 0.0s] */
{
real_T tmpRead;
/* Inport: '<Root>/In2_2s' */
Rte_Read_ReceivePort_In2(&tmpRead);
/* Update for RateTransition: '<Root>/RateTransition' incorporates:
* DiscreteIntegrator: '<Root>/Integrator'
*/
Rte_IrvIWrite_Runnable_2s_IRV1(rtDW.Integrator_DSTATE);
/* Update for DiscreteIntegrator: '<Root>/Integrator' */
rtDW.Integrator_DSTATE += 2.0 * tmpRead;
}
As it can be observed from the code above, the explicit case can be considered buffered in the sense that "tmpRead" is used in the algorithm instead of direct calls to "Rte_Read".
This is required in order to make code and simulation behaviors match, because, in Simulink, a signal is always buffered, and there is no notion of a signal line changing value in the middle of a time step between downstream blocks reading it.
0 Kommentare
Weitere Antworten (0)
Siehe auch
Kategorien
Mehr zu AUTOSAR Calibration and Measurement Data finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!