Filter löschen
Filter löschen

How to decide the sampling time in powegui block in discrete mode?

4 Ansichten (letzte 30 Tage)
Praveen Kumar
Praveen Kumar am 26 Jul. 2018
Beantwortet: Sabin am 13 Jan. 2023
For example, a model of DC-DC converter (boost), how to decide the sampling time in powergui block to run in discrete mode? I have checked different values of sampling time and it greatly effect the system results.

Antworten (1)

Sabin
Sabin am 13 Jan. 2023
We choose the sample time depending on the system dynamics, check the Nyquist–Shannon sampling theorem. The sample time must be small enough to capture the transient. When we have electrical systems with switching devices we also need to consider the switching frequency and then we need to oversample the plant so we get enough samples for each switching period.

Kategorien

Mehr zu Power and Energy Systems finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!