Simulink Stop Simulation... find out which one stops the simulation

5 Ansichten (letzte 30 Tage)
Norbert Thek
Norbert Thek am 11 Apr. 2018
Beantwortet: TAB am 27 Apr. 2018
Hello
We have a Simulink model which contains several Stop Simulation blocks. The problem for me is to find out which one actually stopped the simulation.
The problem is I also it's running automatically so some logging into the console instead of popup messages or something similar.
Also, it would be nice to do this without changing the model itself (replacing the stop blocks) because I receive them from external and this would be quite some work always to replace the blocks.

Antworten (1)

TAB
TAB am 27 Apr. 2018
You can log the Input signals of the Stop Simulation block to base workspace. After simulation is stopped, analyzed the logged variables. Signal which changed to true is responsible for stopping simulation.

Kategorien

Mehr zu Prepare Model Inputs and Outputs finden Sie in Help Center und File Exchange

Produkte

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by