Adding a delay to input reading in Simulink

4 Ansichten (letzte 30 Tage)
Sarah
Sarah am 15 Aug. 2017
Beantwortet: Brian Hannan am 17 Aug. 2017
I am trying to delay the input of an analog reading so that it only reads every 10 seconds, while the rest of the program still runs. I tried the variable time delay but that didn't give me the result I wanted (although it is possible I am using it incorrectly). Any ideas? I don't want to delay the entire model, just this one input.

Antworten (1)

Brian Hannan
Brian Hannan am 17 Aug. 2017
You can use a Sample and Hold block for this. Or you can create a trigger signal with a 10-sec. period to drive a simple enabled subsystem that just passes its input signal value.

Kategorien

Mehr zu Arduino Hardware finden Sie in Help Center und File Exchange

Produkte

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!