I want to set all values bigger than one to 255. Matlab Code would be easily A(A>1) = 255;
But which Simulink blocks can I use to do this? Thank you!
0 Kommentare
Akzeptierte Antwort
AbhimanyuSingh
am 8 Aug. 2017
You Can use the Switch Block present in the /Simulink/Signal Routing/Switch In block properties you can select the 'Threshold' property value as 1 and 'Criteria for passing input' as "u2>Threshold", as shown in the attached image: