Simscape: Linear transformer open circuit error

8 Ansichten (letzte 30 Tage)
Ryan
Ryan am 23 Mai 2017
Beantwortet: Joel Van Sickel am 2 Sep. 2020
Hello,
I'm trying to model a full-bridge DC-DC converter in simscape. I have the model built using ideal switches for the mosfets with a simple switching scheme. However, when I run the model, even though the simulation time is 0.05s it comes up with an error that at t=8s, the linear transformer is "open-circuited" because a couple switches are off simultaneously. This off-time should happen and is normal for the switching scheme.
I've attached a couple pictures of my diagram and error.
Would this error be because of no anti-parallel diodes with the switches?
Thanks!

Antworten (1)

Joel Van Sickel
Joel Van Sickel am 2 Sep. 2020
Hello Ryan,
yes, you can create circuits that our tool cannot simulate with this topology. If you include things like diodes and snubbers, this can solve the problem.
Regards,
Joel

Kategorien

Mehr zu Simscape Electrical finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by