Load flow convergence problem
9 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hello,
I have a problem with the attached Simulink Scheme. The generator has been put as a Swing bus, while the load as a PQ bus I have tried to run a load flow simulation on the scheme, but it seems I have no convergence.
What I have noticed is that: -By removing the PI section line, while maintaining all the rest, the load flow actually converges to a solution. Of course, same goes if remove both PI section line and the transformer. -By reducing the load (up to 14MW and up to 14Mvar) the system still converges, even if I keep the PI section line. -By replacing the load (a R-L parallel load) with an R-L series load (of equal P and Q) the system still converges.
Could you please help me figuring out what the problem is? Thanks in advance, Davide
2 Kommentare
Franklin Ngo
am 19 Mai 2019
Hello,
I checked your system. Your problem is about transient stability. The maximum power: Pmax = E'*Eb/X ( for more details, please read the chapter 13. transient stability. - 13.1 an elementary view of transient stability - book: [prabha kundur] power system stability and control). Your power is too large, then your impedance have to be reduced. Please check the attached file.
Kamilu Sanusi
am 9 Mär. 2023
@Franklin Ngoplease I am similar problem, on IEEE 9 bus system, if i set my load as constant impedance load, the active power injected at the generator bus becomes greater than the specified mechnical power input. The active and reactive power PL & QL of the load also rises.
Please what is the likely problem, all other loads are okay
Thank you
Antworten (1)
Willim
am 29 Nov. 2018
Thank you for sharing the problem. I would like to contact you if you would like to help each other in this problem.
0 Kommentare
Siehe auch
Kategorien
Mehr zu Power and Energy Systems finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!