I try to connect a ground to the Controlled PWM Voltage block in the -ref port but it cannot be done as, some software or gui problem exists. The same problem appeared with other ports of this block. IS IT SOFTWARE BUG or AM I trying to do something "illegal" given the properties of the blocks I am trying to connect???
I use Simulink 7.6(R2010b)
Thanks

 Akzeptierte Antwort

Kaustubha Govind
Kaustubha Govind am 30 Mär. 2012

3 Stimmen

You cannot connect Simulink components to SimScape (SimElectronics) components. Try using the Electrical Reference block instead of the Ground block from the Simulink library.

2 Kommentare

Andreas
Andreas am 30 Mär. 2012
Ok thank you Kaustubha. I did that and i did make it to connect the "ground". I first tried Simulink PS converter for that but it did not work so ELECRICAL REFERENCE block seems to do the job correctly.
Tejaswini Rao
Tejaswini Rao am 25 Jun. 2017
Thank you. I was stuck for many days. Your answer helped me.

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)