PROBLEM SIMULINK CONNECTING BLOCKS
27 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Andreas
am 30 Mär. 2012
Kommentiert: Tejaswini Rao
am 25 Jun. 2017
I try to connect a ground to the Controlled PWM Voltage block in the -ref port but it cannot be done as, some software or gui problem exists. The same problem appeared with other ports of this block. IS IT SOFTWARE BUG or AM I trying to do something "illegal" given the properties of the blocks I am trying to connect???
I use Simulink 7.6(R2010b)
Thanks
0 Kommentare
Akzeptierte Antwort
Kaustubha Govind
am 30 Mär. 2012
You cannot connect Simulink components to SimScape (SimElectronics) components. Try using the Electrical Reference block instead of the Ground block from the Simulink library.
2 Kommentare