DAQ with ENET-9163 and NI 9237 National Instruments

2 Ansichten (letzte 30 Tage)
Dirk
Dirk am 14 Feb. 2012
Bearbeitet: Vinh Dang am 5 Mär. 2015
Hello,
I can't open a channel of the NI 9237 Device in Matlab using R2011a is it a device support problem or is there any solution? That's the device info i'm getting:
>> get(deviceInfo)
IsSimulated: false
Vendor: National Instruments
ID: 'ENET-14E1636'
Model: 'ENET-9237'
Subsystems: empty
Description: 'National Instruments ENET-9237'
RecognizedDevice: false
and when i want to open a analoginput:
s.addAnalogInputChannel('ENET-14E1636', 'ai0', 'Voltage');
??? The requested subsystem 'AnalogInput' does not exist on this device.
Thanks for any help!

Antworten (2)

Manisha
Manisha am 21 Feb. 2012
Hi Dirk,
Support for NI 9237 was added in R2011b. NI 9237 supports only bridge measurements, so if you use R2011b , you should be able to use this device as
s = daq.createSession('ni');
s.addAnalogInputChannel('Dev5', 0, 'Bridge');
Look at this demo for more information on bridge channels.
Hope that helps,
Manisha

Vinh Dang
Vinh Dang am 5 Mär. 2015
Bearbeitet: Vinh Dang am 5 Mär. 2015
Hello, In my application, I have a cDAQ configuration with AI modules 9234 (for accelerometers), 9237 (for pressure and load cell) and 9215 (for proximity and temperature). All modules are put in one chassis cDAQs-9178. What is the valid sampling rate for this?
Thanks for your help!

Kategorien

Mehr zu Simultaneous and Synchronized Operations finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by