No Flow in a basic hydraulic system

7 Ansichten (letzte 30 Tage)
alarson52
alarson52 am 16 Mai 2016
Kommentiert: alarson52 am 13 Jun. 2016
See attached picture. I have modeled a very simple hydraulic system and pressure readings are as expected, but I am reading no flow. I've double-checked all of my parameters and nothing seems out of line. What am I missing here?
  2 Kommentare
Mika Herranen
Mika Herranen am 10 Jun. 2016
You need a 'Hydraulic flow rate source' instead of tank.
alarson52
alarson52 am 13 Jun. 2016
Actually, the tank is fine. Sebastian's answer is correct. The system works fine if the pressure gauge is connected in parallel.

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

Sebastian Castro
Sebastian Castro am 11 Jun. 2016
I think the problem is your Hydraulic Pressure Sensor is connected in series, and is acting as an infinite resistance. Flow sensors go in series; pressure sensors go in parallel.
Make sure you connect that sensor in parallel, so there is a flow path from the tank all the way through the reference.