Filter löschen
Filter löschen

System Identification - Modelling data, low fit

1 Ansicht (letzte 30 Tage)
Brattv
Brattv am 18 Apr. 2016
Bearbeitet: Brattv am 18 Apr. 2016
Hi, I am trying to estimate a process modell by a set of input and output data, but iam uncertain about the abilities and limitations of the methods i am trying. I have started by both normalizing and detrending my dataset, as shown in the figure below. The input data is an "on/off" parameter that have been choosen to be either -0.3 or 0.3 (but can be changed if it is advised).
My original thought was to attempt to modell the process by either ARX or ARMAX estimation. I tried to start with an ARX estimation where the AIC said na=10, nb=10, nk=1, with a 26.17% fit as shown below
This was clearly a higher polynomial order and worse fit than i originally had hoped. The ARMAX estimated resulted in much of the same result.
I would like to ask for some advise for my further work. Is there some more suitable method to solve the modell estimation, or will it be a hard nut to crack? I have attached the system identification toolbox file for the dataset.

Antworten (0)

Kategorien

Mehr zu Linear Model Identification finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by