Simulink connection without drawing lines?

74 Ansichten (letzte 30 Tage)
Kevin Bachovchin
Kevin Bachovchin am 17 Jan. 2016
Beantwortet: Pranav Pillai am 25 Jan. 2023
Hello,
Is there a way to connect two nodes in a Simulink diagram without drawing the lines (such as using ports or something like that)? I'm trying to simulate a relatively complex electric circuit in Simulink and if I try to draw all the lines, there's going to be a lot of lines overlapping each other. The circuit would be much cleaner to view if I could connect through ports at a few places instead.
Thank you,
Kevin

Akzeptierte Antwort

Walter Roberson
Walter Roberson am 17 Jan. 2016
Would it perhaps make sense to design pieces as "subsystems" ? If I understand correctly, subsystems can be represented as having input and output ports, so your lines would at worse go to the edge of the subsystem, without having to have each external line be drawn to each internal location that needs it.
  3 Kommentare
Walter Roberson
Walter Roberson am 17 Jan. 2016
It is not immediately obvious that you cannot do that; http://www.mathworks.com/help/simulink/ug/creating-subsystems.html
What happens if you create an existing circuit with a DC voltage input, select the parts after that in the circuit, and put them in a subsystem?
Are you using basic Simulink or are you using SimElectronics?
Kevin Bachovchin
Kevin Bachovchin am 17 Jan. 2016
Thanks that worked. When I selected part of the circuit and put it into a subsystem it made the ports as hexagon "connection ports" blocks, which can connect to circuit elements, rather than oval shaped "in" and "out" blocks, which I was trying before. To answer your question, I'm using the circuit element under Simscape/FoundationLibrary/Electrical.
One additional question I have is: When I click on the voltage source block, there is a parameter called “voltage”. Is there a way to set that voltage equal to a signal port input to the subsystem? (ie, the voltage source value is determined from a different controller subsystem)

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (2)

Matthew Kapp
Matthew Kapp am 3 Aug. 2017

Pranav Pillai
Pranav Pillai am 25 Jan. 2023
You can use in and out too if you are using a subsystem

Kategorien

Mehr zu Conditionally Executed Subsystems and Models finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by