How to solve the error>>> Error evaluating parameter 'InputValues' in 'crankshaf​t_jointact​/Lookup Table'

I am currently using SIMULINK version-7.9 [2012 A]
WHILE using the simulink model which was running on other Simulink version.
It is showing error as >>> Error evaluating parameter 'InputValues' in 'crankshaft_jointact/Lookup Table' and on my model look-up table is marked as RED means the look-up table which is being used in higher version is not compatible to lower version or it is missing some configurable files , what are required for running the model.

1 Kommentar

another error it is showing below that line is Undefined variable "Force_Table" or class "Force_Table.crank_angle". Does it missing the configured entity "Force_Table" & class "Force_Table.crank_angle" ?

Melden Sie sich an, um zu kommentieren.

 Akzeptierte Antwort

If the model was created in a later version, then you may need to open it in that later version and request to save it with backwards compatibility. Models created in one version might not be usable in any previous version unless you save for compatibility.

4 Kommentare

Yes , It may be absolutely correct. But I don't have new version of Simulink to save it for compatibility. So is there any other method to do it?
another error it is showing below that line is Undefined variable "Force_Table" or class "Force_Table.crank_angle". Does it missing the configured entity "Force_Table" & class "Force_Table.crank_angle" ?
If I can re-define >>> undefined variable "Force_Table" then it may solve the problem.
Possibly you could find someone with a new enough Simulink version to save the model for you. (I cannot do it myself as I do not have Simulink.)

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Kategorien

Mehr zu General Applications finden Sie in Hilfe-Center und File Exchange

Produkte

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!