Filter löschen
Filter löschen

Device communication

2 Ansichten (letzte 30 Tage)
Slobodan Djordjevi?
Slobodan Djordjevi? am 7 Dez. 2011
Hi
I need help with reading data from a device. My code :
s1 = serial('COM4');
s1.BaudRate = 9600;
s1.DataBits = 8;
s1.Parity = 'none';
s1.StopBits = 1;
s1.FlowControl = 'none';
s1.Terminator ='CR';
fopen(s1);
fread(s1);
fclose(s1);
delete(s1);
The problem occurs, because I have to send/transmit a macro to the device. Macro is ACK(acknowledgment/006) in ASCII. I don't know how to do this. What should I add to my code?
Thanks a bunch in advance!

Akzeptierte Antwort

Walter Roberson
Walter Roberson am 7 Dez. 2011
fwrite(s1, char(6))

Weitere Antworten (2)

Slobodan Djordjevi?
Slobodan Djordjevi? am 7 Dez. 2011
It worked, thanks!
Now the the data is an array of 1x17 of some numbers 48 48 48 48 46 48 52 13 48 48 48 48 46 48 48 13 10, am I supposed to convert this?
  1 Kommentar
Walter Roberson
Walter Roberson am 7 Dez. 2011
fwrite(s1, char([48 48 48 48 46 48 52 13 48 48 48 48 46 48 48 13 10]))
Please double-check the list of characters. At the very end you have 10 following the 13, which is linefeed following carriage return, but earlier in the sequence you have a carriage return by itself. Very few systems mix carriage return alone with carriage return followed by linefeed.

Melden Sie sich an, um zu kommentieren.


Slobodan Djordjevi?
Slobodan Djordjevi? am 7 Dez. 2011
Nevermind, I did it with char(data).
Thank you Walter!

Kategorien

Mehr zu Data Import and Analysis finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by