Difference in simulation results of continuous and discrete transfer function in simulink
Ältere Kommentare anzeigen
Hi,
I am trying to compare the continuous (s-domain) and discrete (z-domain) implementation of a system in simulink. My model is simple as shown.

My input signal is a sine of amplitude = '1' and frequency = '2*pi*1e3' rad/sec. The discrete domain TF is obtained by using 'c2d' function of Matlab with a sampling time of '1e-5' seconds. But I am getting entirely different responses to the same. It would be of great help if someone can clarify why this is happening.
Many thanks in advance
Karthik R
1 Kommentar
Reyad El-Khazali
am 16 Jan. 2018
Your discrete-time transfer function is wrong. The correct one is: G(z) = [ 0.000986 z^2 + 0.001972 z + 0.000986 ]/[z^2 -1.996z + 0.9999 ] obtained using c2d (N,D, 10^-5, 'Tustin') The simulation of both the continuous and the discrete one were identical.
Akzeptierte Antwort
Weitere Antworten (0)