Currently I'm Taking Control Techniques for PMSM (new), at Current Controller Optimization, Implement MTPA and FWC to optimize your controller. I start taking the task, from 1 to 3 all no issues, but when I take the task 4, and follow the step by step, and checked all the setting are fine, but the output not meet the requirement, checked no error log, please help,

2 Kommentare

Kartikey
Kartikey am 12 Okt. 2026 um 10:36
The screenshot is too zoomed out, so it is difficult to identify the exact cause. As a troubleshooting step, remove the current Vector Concatenate block and add a new one with Number of inputs set to 3. Reconnect the signals and check whether the assessment passes.
Signal Assessment appears to be connected to the V_ao output of the PWM Reference Generator. Verify this connection and the block parameters. Use the task’s Hint section to compare the expected setup with your model.
to understand port and connection of PWM, refer to the PWM Reference Generator documentation.
BEN
BEN am 13 Okt. 2026 um 11:24
Verschoben: Torsten am 13 Okt. 2026 um 12:38
Hi Kartikey,
I have reconnected the overall block diagram multiple times and attempted to adjust some of the parameters. However, I am still unable to achieve the correct output. Could you please provide your guidance and advice?
I has captured the connection and parameter for your referance, may help you to do analizing.
Thank you, Ben

Melden Sie sich an, um zu kommentieren.

Antworten (2)

Kartikey
Kartikey am 14 Okt. 2026 um 12:12

0 Stimmen

From page 9 of the attached PDF, I noticed a possible angle-unit mismatch. The Input mechanical angle unit parameter of the Mechanical to Electrical Position block is set to Radians, so its electrical-position output is also in radians. However, the Theta units parameter of the SinCos Embedded Optimized block is set to Per-unit.
Could you try changing the Theta units parameter to Radians, rerunning the model, and submitting the task again? I think this may resolve the mismatch. Let me know whether the assessment passes after the change.

1 Kommentar

BEN
BEN vor etwa eine Stunde
Thank you very much, after changed the Theta units parameter of the SinCos Embedded Optimized block from Per-unit to Radians is work.

Melden Sie sich an, um zu kommentieren.

BEN
BEN vor 42 Minuten

0 Stimmen

Dear Kartikey,
I am working on the assessment that requires adding the SinCos Embedded Optimized block from the Motor Control Blockset. The instructions specify the path as: Motor Control Blockset → Controls → Math Transforms.
However, in my installed version of MATLAB/Simulink, the block only appears under: Motor Control Blockset → Math Transforms (without the 'Controls' folder).
The block itself is present and functions correctly, but the library hierarchy differs. Could you please confirm if using the block from Motor Control Blockset → Math Transforms is acceptable for the assessment, or if a specific version of the toolbox is required?
Thank you for your guidance.
Best regards, Ben