Control Techniques for PMSM
Ältere Kommentare anzeigen
Currently I'm Taking Control Techniques for PMSM (new), at Current Controller Optimization, Implement MTPA and FWC to optimize your controller. I start taking the task, from 1 to 3 all no issues, but when I take the task 4, and follow the step by step, and checked all the setting are fine, but the output not meet the requirement, checked no error log, please help,

2 Kommentare
Kartikey
am 12 Okt. 2026 um 10:36
The screenshot is too zoomed out, so it is difficult to identify the exact cause. As a troubleshooting step, remove the current Vector Concatenate block and add a new one with Number of inputs set to 3. Reconnect the signals and check whether the assessment passes.
Signal Assessment appears to be connected to the V_ao output of the PWM Reference Generator. Verify this connection and the block parameters. Use the task’s Hint section to compare the expected setup with your model.
Antworten (2)
Kartikey
am 14 Okt. 2026 um 12:12
0 Stimmen
From page 9 of the attached PDF, I noticed a possible angle-unit mismatch. The Input mechanical angle unit parameter of the Mechanical to Electrical Position block is set to Radians, so its electrical-position output is also in radians. However, the Theta units parameter of the SinCos Embedded Optimized block is set to Per-unit.
Could you try changing the Theta units parameter to Radians, rerunning the model, and submitting the task again? I think this may resolve the mismatch. Let me know whether the assessment passes after the change.
1 Kommentar
BEN
vor etwa eine Stunde
BEN
vor 42 Minuten