problem with the power system simulation onramp course

30 Ansichten (letzte 30 Tage)
Fermín
Fermín am 20 Dez. 2024 um 0:05
Kommentiert: Jason am 24 Dez. 2024 um 9:36
hello
someone who has already done this course can help me please?
in the represent power system component point there are a task whitout solution. i don´t know if its a mistake or im doing it wrong. the of the second module. i have done al the step they ask me to but the simulation still not working. i have followed the solution steps to see if its me but no, the simulation still not working. in the follow image as you can see this is the correct way to solve the problem but does not work

Akzeptierte Antwort

Cris LaPierre
Cris LaPierre am 20 Dez. 2024 um 5:07
Bearbeitet: Cris LaPierre am 20 Dez. 2024 um 22:16
I was able to duplicate the issue. This is happening because the default value for one of the Wye-Connected Load block parameters has changed in R2024b.
Under Parasitics, change the Parasitic parallel conductance to 0. Keep the units as 1/Ohm.
Now when you submit, you should pass assuming everything else is correct.
  1 Kommentar
Jason
Jason am 24 Dez. 2024 um 9:36
Just got to this issue myself, was connecting the same output to the signal assessment to the scope to see how it looked on the scope, and form what I could tell there was no issues.
Setting the Parasitic Parallel Conductance to 0 as stated worked for me.
Thanks Cris

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by