I try to tune my PI controller but I always get the error message "Subscript no. 2 is out of range" and "Plant cannot be linearized"
  1 Kommentar
Sumukh
Sumukh am 30 Okt. 2024
Can you please share the Simulink model for better understanding the issue?

Melden Sie sich an, um zu kommentieren.

Antworten (1)

MULI
MULI am 4 Dez. 2024
Bearbeitet: MULI am 5 Dez. 2024
The errors "Subscript no. 2 is out of range" and "Plant cannot be linearized" occur because your model includes switching components (e.g., the Universal Bridge and PWM signals), which can introduce discontinuities that prevent successful linearization.
You can follow the three suggestions below to resolve the issue:
Identify the Plant Using System Identification:
Frequency Response Estimation:
Simplify the Model for Linearization:
  • Replace the switching components (e.g., the Universal Bridge) with averaged switching models or linear approximations.
  • This will smooth out discontinuities and allow the model to be linearized.
  • You can refer to the below link for any further information on linearisation of electrical components: https://www.mathworks.com/help/sps/linearization_techniques.html
After identifying the plant model, load it into the PID Tuner App and then use the app to design and tune the PID controller for desired performance. You can refer to below link for more information on this:
You may refer to the below answer where similar query is addressed