- PS-Simulink/Simulink-PS Converter block is used to connect a physical signal to simulink ouput signal or vice versa, this cannot be used to connect two different simscape components.
- Now in-order to measure/observe the waveform or input given to 'Two-Level Converter' you might have to use some blocks from 'Simscape>Electrical>Specialized Power Systems>Utilities' like Voltage-Current Simscape Interface (gnd) or Current-Voltage Simscape Interface (gnd).
- Two-level converter once connect to 'Voltage-Current Simscape Interface (gnd)' the other port of this block can be connected to corresponding sensor to measure/observe the input.
What is the port compatibility for Simscape blocks?
4 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hi,
Whenever I work with simscape, I have this issue. Where is the port compatability defined?? I couldnt find any documentation related to this.
Some of the simscpae blocks are not connectable to any other directly in Simulink. Also, the PS-Simulink converter doesnt help
Here(in the fig), you can see that the A port is not connecting to anything. I tried to use all possible ways. My main aim is to connect scope to it and check the waveform. But its not connecting simply. I tried using a voltage sensor, which is a simscape element. But still its not connecting.
Ps: its not the issue of input ports or output ports. The conservative ports ABC in the above image are output ports of the block.
0 Kommentare
Antworten (1)
Divyanshu
am 1 Aug. 2024
Hi Raghuveer,
There is no such documentation which has information about port compatibility of all Simscape blocks. Generally, two blocks which belong to different Simscape Components cannot be connected directly.
4 Kommentare
Divyanshu
am 2 Aug. 2024
Hi,
I just wanted to direct you towards using the components from same Simscape Paradigm. The blocks which I mentioned earlier are just example which can be used with 'Two-level converter', they may not be required/relevant in your use-case.
Now if you want to observe certain values of 'Two-level converter' on scope block directly:
Here are the measurement blocks which you can directly connect to scope block on one end and other end to 'Two-level converter': 'Current Measurement','Voltage Measurement','Impedance Measurement' etc.
The path to these blocks is: Simscape> Electrical > Specialized Power Systems > Sensors and Measurements.
You may have to choose appropriate block depending upon the use-case.