- "PortLineLength" is assigned to "pll" which is not defined. It should be assigned with a scalar value.
- "Conductor" should a "metal" object. However, it is assigned as "capacitor.Conductor" which is not a valid metal object.
Issues with getting capacitance using Interdigitalcapacitor both capacitance value and RF values.
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
When runnign the following commands:
capacitor = interdigitalCapacitor(NumFingers=5,FingerLength=4500e-6,FingerWidth=332e-6,FingerSpacing=206e-6,FingerEdgeGap = 87e-6,TerminalStripWidth=330e-6,PortLineWidth=8000e-6,PortLineLength=pll,Height=20e-6,GroundPlaneWidth=1,Conductor=capacitor.Conductor)
capacitance(capacitor,10e9)
I do not get any values for the capcitance - not DC or RF..
Also, when i run it MATLAB window does not pruce any resuta and i cannot "stop" the run and have to kill the matlab process.
0 Kommentare
Antworten (1)
Sayan
am 6 Mai 2024
Hi Alkim Akyurtlu,
The "PortLineLength" and the "Conductor" properties are not properly defined in your "interdigitalCapacitor" object.
You can refer to the following code snippet with modified values of "PortLineLength" and "Conductor".
%creating a conductor of 'copper'
m = metal('copper');
%Setting the "PortLineLength" to "0.01" and "Conductor" to "m"
capacitor = interdigitalCapacitor(NumFingers=5,FingerLength=4500e-6,FingerWidth=332e-6,FingerSpacing=206e-6,FingerEdgeGap = 87e-6,TerminalStripWidth=330e-6,PortLineWidth=8000e-6,PortLineLength=0.01,Height=20e-6,GroundPlaneWidth=1,Conductor=m);
capacitance(capacitor,10e9);
This runs for me and I get the following output.
You can further refer to the following documentation to know more on "interdigitalCapacitor".
Hope this helps in resolving the issue.