- Line current that we measure must be converted to phase current
 - An offset (-(120/N)*pi/180) is needed for electrical angle used in transformation of current from abc to dq. N is the number of polepairs.
 
Setting offset in torque control and Delta connection
    9 Ansichten (letzte 30 Tage)
  
       Ältere Kommentare anzeigen
    
    adhavan d
 am 30 Aug. 2023
  
    
    
    
    
    Kommentiert: adhavan d
 am 27 Sep. 2023
            Hi,
my model is based on ipmsm torque control with delta connection.
So,I used 30 degree (-0.523599 - rad) offset wwith electrical theta for 500 rpm and 60 nm.it works.
but when I used 30 degree(-0.523599  radian) offset with electrical theta for 8500 rpm and 16 nm,The machine  torque can not been met request torque.
How to set offset value for all speed and torque in delta connection.
0 Kommentare
Akzeptierte Antwort
  Sabin
    
      
 am 21 Sep. 2023
        When using delta connection there are 2 changes that are needed:
The Three-Phase PMSM Drive example in Simscape Electrical shows how to use the controller in case of wye and delta. I hope this helps. 
Weitere Antworten (0)
Communitys
Weitere Antworten in Power Electronics Control
Siehe auch
Kategorien
				Mehr zu Permanent Magnet finden Sie in Help Center und File Exchange
			
	Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!