PID Autotuner block issues
10 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I am currently struggling quite a bit to get any sort of value out of either of the PID Autotune blocks (open-loop / closed-loop).
My model includes a motor output and pressure sensor input, where the input to PID (pos/neg) is in pressure and the output value to the motor is converted to an I2C (0-255) control value. - Both of the following models are run on Com_Port_4 using "Monitor & Tune", and I am "activating" the start/stop input about midway.
I have set everything up according to the EXAMPLE model, however, when I run the closed-loop block version it compiles fine and end the run successfully, only the <P>, <I>, <D> output (displays) are blank?
When I run the open-loop version, it runs the entire duration till stop time, but throws this error right at the end (also no P, I, or D values are output?):
ERROR:
External Mode Open Protocol CheckData command failed
Caused by:
* Multiple errors detected.
* XCP internal error: timeout expired, in response to XCP SYNCH command
* Error detected while trying to disconnect Simulink from target application.
* XCP error: XCP internal error: No server connected
0 Kommentare
Antworten (2)
Sivapriya Srinivasan
am 25 Mai 2023
Hey Antony Smith,
It seems like you're encountering some issues with the PID Autotune blocks in your model. Let's try to troubleshoot the problems you're facing.
Closed-Loop Autotune:
The fact that the <P>, <I>, <D> outputs are blank suggests that there might be an issue with the block's configuration or signal connectivity. Here are a few things you can check:
1.Ensure that the input and output signals are correctly connected to the PID Autotune block.
2.Double-check the block parameters, such as the sample time, input/output signal types, and limits. Make sure they are set correctly for your system.
3.Verify that the pressure sensor input signal is within the expected range for the Autotune block.
4.Confirm that the Autotune block is correctly configured to use the pressure input for tuning the PID parameters.
5.Check if there are any error messages or warnings in the simulation console or MATLAB command window that could provide additional information about the issue.
Open-Loop Autotune:
The error message you provided suggests a communication problem between the Simulink model and the target application. Here are some steps to troubleshoot the issue:
1.Make sure that the target application is properly connected and configured to communicate with Simulink. Check the connection settings, such as the port number and communication protocol (e.g., XCP).
2.Verify that the target application is running and ready to receive commands from Simulink.
3.Check if there are any firewall settings or antivirus software that might be blocking the communication between Simulink and the target application. Temporarily disabling them can help identify if they are causing the issue.
4.If you have multiple instances of the target application running, ensure that the correct instance is connected to Simulink.
5.Restarting both the target application and Simulink, and then reconnecting them, may also resolve the communication problem.
If the above troubleshooting steps do not resolve the issues, it may be helpful to consult the documentation or support resources for the specific PID Autotune blocks you are using. Additionally, sharing more details about your model configuration and the specific blocks you are using could assist in providing more targeted assistance.