Warning: The value of enumeration member 'VT_OK' differs from when the enumeration was saved. 'VT_OK' will be loaded with the new value.

10 Ansichten (letzte 30 Tage)
When I run the Test Sequence created in Simulink Test Manager, I get the following warnings in the command window:
Warning: The value of enumeration member 'VT_OK' differs from when the enumeration was
saved. 'VT_OK' will be loaded with the new value.
Warning: The value of enumeration member 'IGN_SNA' differs from when the enumeration was
saved. 'IGN_SNA' will be loaded with the new value.
Warning: The value of enumeration member 'VSL_INACTIVE' differs from when the
enumeration was saved. 'VSL_INACTIVE' will be loaded with the new value.
Please let me know how to remove this warning.

Akzeptierte Antwort

Nishan Nekoo
Nishan Nekoo am 9 Nov. 2022
These warnings can be resolved as follows:
1) Find the Simulink.Parameter objects or other data objects in the data dictionary that use the enumeration mentioned in the warning message
2) Make minor modifications to the data object (e.g., change the description) and then save the changes
  2 Kommentare
Montina
Montina am 10 Nov. 2022
Bearbeitet: Montina am 10 Nov. 2022
Thanks Nishan.
I have resolved this error by following the below steps:
  1. Identiifed the args.mat in which data objects were defined which caused the enumeration waning message.
  2. Reloaded only args.mat.
  3. Resaved all its simulink parameters objects in the agrs.mat without making any modifications