minibatchqueue or arrayDatastore drops my data precision from double to single

1 Ansicht (letzte 30 Tage)
I get XTrain from MNIST by processImagesMNIST and put it on GPU, so its type is gpuArray dlarray.
then I use these code to make minibatches:
```
miniBatchSize = 128;
dsTrain = arrayDatastore(XTrain,IterationDimension=4);
% numOutputs = 1;
mbqTest = minibatchqueue(dsTrain,1, ...
MiniBatchSize = miniBatchSize, ...
MiniBatchFcn=@preprocessMiniBatch, ...
MiniBatchFormat="SSCB", ...
PartialMiniBatch="discard");
% numObservationsTrain = size(XTrain,4);
% numIterationsPerEpoch = ceil(numObservationsTrain / miniBatchSize);
% numIterations = numEpochs * numIterationsPerEpoch;
%% test batch order
i=0;
while hasdata(mbqTest)
i = i+1;
x = next(mbqTest);
if ~hasdata(mbqTest)
disp(i)
end
end
```
And I find that x is single gpuArray dlarray, XTrain is gpuArray dlarray.
I wonder which part makes it lower the precision.
And how to avoid this?
  1 Kommentar
Runcong Kuang
Runcong Kuang am 29 Sep. 2022
I find that minibatchqueue has a 'name,value' pair which is outputCast, 'single' as default. So I assign 'double' to it. But I haven't checked if the GPU training process does use single precision, as mentioned by @Walter Roberson.
But thanks for your input @Walter Roberson.

Melden Sie sich an, um zu kommentieren.

Antworten (1)

Walter Roberson
Walter Roberson am 28 Sep. 2022
Gpu training does not support double precision. If you look at the available options, precision cannot be selected.