help required for fixed point conversion
3 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I am using R14A and I have modelled angle tracking observer algoirthm in simulink. I have simulated model wih floating point and it works well. I used fixed point advisor. Although there are no errors, but the output is zero. Can anybody help us withthis.
5 Kommentare
Antworten (2)
Ayush Kumar Jaiswal
am 19 Jun. 2022
Bearbeitet: Ayush Kumar Jaiswal
am 19 Jun. 2022
The problem of getting all the output as zeros could potentially be related to the proposed data type settings which results in overflows. You could verfiy that in the histograms produced after simulation.
Try increasing the word length in the Settings section of the fixed point tool, allowing more room for calculation and hence avoiding overflows.
Thanks
9 Kommentare
Ayush Kumar Jaiswal
am 20 Jun. 2022
Float subsystem also gives zeros as an output. You mean to say that after converting to fixed point both subsystems are giving zeros? Then please share the un-converted model.