How can I solve dimension problem? Simulink
4 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hasan Atacan Tosun
am 26 Mai 2022
Beantwortet: Walter Roberson
am 27 Mai 2022
Hello everyone,
I am getting this error
" Error in port widths or dimensions. 'Output Port 1' of 'untitled/From29' is a one dimensional vector with 1369 elements."
saveV.mat size 1370x2 [time,Velocity]
saveACC.mat size 1370x2 [time,Acceleration]
both like,
0 3
1 5.9
2 4
. .
. .
. .
Also I do not know why size decreased from 1370 to 1369.
Thank you...
2 Kommentare
Walter Roberson
am 26 Mai 2022
Sample Time is not number of samples! It is related to the rate at which the block is considered to output samples.
Akzeptierte Antwort
stozaki
am 27 Mai 2022
The Logical operands input of the If block must be a scalar signal. It's a block specification.
Also, the output of the If block should be connected to the Action Subsystem. It is also a block specification.
0 Kommentare
Weitere Antworten (1)
Walter Roberson
am 27 Mai 2022
You need to transpose the data in the file. The first row is the time stamps and rows after that are samples for that time. You have two times and 1369 values.
This is unlike From Spreadsheet, which treats the first column as time if I recall correctly.
0 Kommentare