Either:
a) double click on the Audio Device Writer block and uncheck the box for Inherit Sample Rate from Input and set the desired sample rate in the Sample Rate parameter
or
b) put a Zero Order Hold Block on the line feeding the ADW block and set the Sample Time parameter as the inverse of the desired sample rate