Question regarding Frequncy component
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
Lets suppose we are having two cos functions having frequency 500 Hz and 250 Hz. when these cos function are multiplied to make a single signal, the frequency spectrum shows frequency components at 750 Hz and 250 Hz
Now the minimum sampling freq for this signal(which is being multiplied) will be 1500 Hz. Is this true
0 Kommentare
Akzeptierte Antwort
Wayne King
am 1 Okt. 2011
Yes, that's correct there will be frequency components at [-750 -250 250 750] so the bandwidth is 1500 Hz, you have to sample at least at 1500 Hz.
0 Kommentare
Weitere Antworten (0)