I have a simple Simulink model, looking like the following:
I want the sum (at the right) to be equal to zero, so I have the following equation:
Input*ss1 + Input*K*ss2 = 0
Input * (ss1 + K*ss2) = 0
ss1 + K*ss2 = 0
K = -inv(ss2)*ss1
Both ss1 and ss2 are linear state space with one input, and one input. However, when calculating K, I get a descriptor state space (a,b,c,d AND e), which I cannot (or do not know how to) enter in Simulink. When running the simulink model without the 'K.e', it does not add up to zero.
Can someone tell me how to calculate K, so I don't get the descriptor SS? Or how to use the descriptor SS in Simulink?
Regards,
Thijs
  4 Kommentare
Thijs
Thijs am 11 Apr. 2014
Anyone?
Thijs
Thijs am 15 Apr. 2014
Is there noone that can help me on this one?

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

Arkadiy Turevskiy
Arkadiy Turevskiy am 28 Apr. 2014
You can implement descriptor state space systems in Simulink using LTI System block from Control System Toolbox.

Weitere Antworten (1)

Fu Zhang
Fu Zhang am 27 Mär. 2019
In 2018b, Simulink introduced descriptor state space block, which is a built-in block that support sparse parameter. Details can be found here : https://www.mathworks.com/help/simulink/slref/descriptorstatespace.html