GETSNAPSHOT timeout error after adjusting camera settings
2 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hello,
I am using a Webcam (Logitech C160) to capture Images using the Image acquisition toolbox (V 3.5) in Matlab 7.10.0.499. When ever I adjust the camera settings (brightness, exposure etc.) and try to capture an image afterwards I get a timeout error.
??? Error using ==> imaqdevice.getsnapshot at 65 A timeout occurred during GETSNAPSHOT.
Interestingly, when I run the preview window during the setting change I can see the camera changing brightness, exposure etc... and it works fine, however if I stop the preview, then start it after changing the settings the preview window stays black.
If I leave the preview window running during the change, the GETSNAPSHOT function seems to work fine. As soon as I stop the preview I get the error message again.
Running the snapshot function before the change without the preview works fine.
Any ideas would be appreciated!
Sam
0 Kommentare
Antworten (1)
Chirag Gupta
am 13 Jul. 2011
Can you try and set the trigger to Manual and then try and acquire the snapshot.
triggerconfig(vidobj, 'manual');
% change properties
start(vidobj)
snapshot = getsnapshot(vidobj);
% Call the STOP function to stop the device.
stop(vidobj)
You could also change the Timeout property of the videoinput object.
2 Kommentare
Chirag Gupta
am 14 Jul. 2011
I belive TimeOut is a property in the videoinput object.
vidObj.Timeout = 15;