problem in designing state feedback controller
2 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Abdulaziz AlKuwari
am 5 Jan. 2014
Kommentiert: Abdulaziz AlKuwari
am 5 Jan. 2014
I derived a model that is a Mimo model with 3 inputs and one output. I wanted to design a state feedback controller to control only one of the input because the others are constants that cannot be physically controlled. The approach I addressed is finding the transfer function of the desired control input to the output. Then I convert the system to state space so it turns to be siso system. Is my approach correct?
Thank you
0 Kommentare
Akzeptierte Antwort
Azzi Abdelmalek
am 5 Jan. 2014
You can consider your model as SISO with two disturbance signals. Set those two constant signal to 0 and find the transfer function, and convert it to whatever you want (state space representation, or others)
Weitere Antworten (0)
Siehe auch
Kategorien
Mehr zu Classical Control Design finden Sie in Help Center und File Exchange
Produkte
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!