Thyristor 6-Pulse Generator
Generate thyristor 6-pulse waveform in single-pulsing mode
Libraries:
Simscape /
Electrical /
Control /
Pulse Width Modulation
Description
The Thyristor 6-Pulse Generator block implements a thyristor 6-pulse waveform generator in single-pulsing mode.
You can use this block to perform phase-controlled AC-to-DC conversion by:
Measuring the synchronization angle of the AC signal with a phase-locked loop
Controlling a thyristor converter network with the pulses generated by this block
Model
The figure shows the equivalent circuit for the Thyristor 6-Pulse Generator.
Based on the synchronization angle, theta, and the firing angle, alpha, the block internally generates six ramps, one for each of the pulse elements in its output vector.
The block generates a pulse at one of the outputs when the associated ramp meets or crosses the specified firing angle in the upward direction. This figure shows such a pulse generation mechanism for one of the outputs.
Set the pulse ordering strategy to modify the distinct phase-shift of each ramp, and as a result, the order of generated pulses:
Set the
Pulse ordering
property toSequential device order
to generate pulses in sequential order. Use this strategy to generate pulses for the Converter (Three-Phase) block or other thyristor networks that use sequential ordering.Set the
Pulse ordering
property toNatural order of commutation
to generate pulses in the natural order. Use this strategy to generate pulses for thyristor networks that use natural ordering.
Examples
Ports
Input
Output
Parameters
References
[1] Pelly, B. R. Thyristor Phase-Controlled Converters and Cycloconverters: Operation, Control, and Performance. New York, NY: John Wiley & Sons, Inc., 1971.
Extended Capabilities
Version History
Introduced in R2017b