Check usage of Simulink function in Stateflow
Check ID:
mathworks.jmaab.na_0042
Guideline: na_0042: Usage of Simulink® functions
Description
Checks the usage of Simulink functions in Stateflow.
This check requires Simulink Check™ and Stateflow® licenses.
Check Parameterization
This check does not include sub-checks because the MAB modeling guideline provides only one sub ID.
For reference, the MAB guideline sub ID(s) that are recommended for use by the NA-MAAB and JMAAB modeling standards organizations are:
NA-MAAB — a
JMAAB — a
Results and Recommended Actions
Condition | Recommended Action |
---|---|
Input or output arguments passed to Simulink Functions are not data or variables of Local scope. | Modify the chart data or variables scope to Local. |
Input or output arguments passed to Simulink Functions use data or variables of output scope. | Input or output arguments passed to Simulink Functions should be a mixture of data or variables of Local scope and/or Input scope. |
Simulink functions are not called from multiple locations within the chart. | Make sure Simulink functions are reused. |
Capabilities and Limitations
This check does not analyze if Simulink functions are called every time step.
Runs on library models.
Allows exclusions of blocks and charts.
Analyzes content of library-linked blocks. By default, the input parameter Follow links is set to
on
.Analyzes content in masked subsystems. By default, the input parameter Look under masks is set to
graphical
.