Hauptinhalt

Download Battery Data

Since R2025a

This example downloads hybrid pulse power characterization (HPPC) test data performed on a BAK N18650CL-29 18650 type lithium-ion cell [1]. This data is required to run multiple examples in Simscape™ Battery™.

A BioLogic© BCS-815 eight-channel battery tester, equipped with standard cables, accessories, and thermocouples, performed the battery HPPC tests [2]. The test chamber maintained the temperature and humidity control. To measure the temperature, the tester used the Agilent© 34972A data acquisition system equipped with multiplexer capabilities. The system tested three different samples. The test was reproducible each time. The cells were tested at five different uniform chamber temperatures: 0°C,10°C,25°C,35°C, and 45°C.

References

  1. Zhengzhou Bak Battery Co.,LTD, "Specification For Lithium-ion Rechargeable Cell. Cell Type : N18650CL-29".

  2. Anandaroop Bhattacharya, Subhasish Basu Majumder. "Experimental data collected with Biologic BCS-815 8-channel battery tester for battery HPPC test". Indian Institute of Technology (IIT) Kharagpur, India.