displayCaptureCondition(DC) displays the
signal value comparisons and logical operator that define the overall capture condition.
DC is a customized data capture object.
This example uses a customized data capture object,
DC, that defines two signals for both trigger and data capture.
Signal A is 1 bit and signal B is 8 bits.
Enable capture condition logic.
DC.EnableCaptureCtrl = true;
To enable capture condition logic, you must select the Include capture
condition logic parameter while generating the data capture IP core using
the FPGA Data Capture Component Generator tool.
Set up a capture condition to capture data when the FPGA detects a high value on
signal A at the same time as signal B is greater
than 7.
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window.
Web browsers do not support MATLAB commands.