Beantwortet
Initial condition from external source for discrete integration diuring runtime
The value of "mec_init_pos" could be constant or dynamic, but in this case, only its value at the begining of the simulation (e....

mehr als ein Jahr vor | 1

| akzeptiert

Beantwortet
Function Call Trigger Problem
This "Outport" block seems to output a function call trigger. The message tells you what type of block can receive this signal. ...

mehr als ein Jahr vor | 0

Beantwortet
A few basic Simulink/Simscape questions
run forever (tstop = inf) Yes. Set the simulation stop time to be inf store the trailing 10000 points Yes. Limit the data poi...

mehr als ein Jahr vor | 0

| akzeptiert

Beantwortet
How the Delay one step block and stop time ( simulation time) infuence each other on simulink?
If you don't specify the step size or it is auto, the step size is automatically adjusted, influnced by simulation stop time and...

mehr als ein Jahr vor | 0

Beantwortet
Simulink model output heavily dependent on relative tolerance
Not typical but is for a stiff system. Choose a stiff solver. https://www.mathworks.com/help/matlab/math/solve-stiff-odes.html

mehr als ein Jahr vor | 0

Beantwortet
Issue in creation of test harness of a Simulink state in stateflow or creation of harness of a subsystem present in simulink state of stateflow.
I don't think a "system under test" can be a "state" in a state chart. A typical "system under test" has inputs, while a "state"...

mehr als ein Jahr vor | 0

Beantwortet
Generate signal according to the the rising edges of two pulse generators in simulink.
A triggered subsystem shoud suffice. https://www.mathworks.com/help/simulink/slref/triggeredsubsystem.html

mehr als ein Jahr vor | 0

Beantwortet
Matlab & Simulink crash at 2nd model run
After first run, execute "clear mex" or "clear functions" in MATLAB Command Window to see if it makes a difference.

mehr als ein Jahr vor | 0

Beantwortet
Avoid reuse of local variables in Embedded coder
That is probably not the correct option. You should try to disable the "Reuse local block outputs" option. https://www.mathwor...

mehr als ein Jahr vor | 0

Beantwortet
Switch multiport switch inputs based on time and order from user
There are many ways to do it. The easiest or most flexible way to do it is probably by using a MATLAB Function block. Use a Cloc...

mehr als ein Jahr vor | 0

Beantwortet
Attempting to turn off Dynamic Memory allocation but struggling to set variable size upper bound
Try allocating the variable in one shot, e.g. obj=struct('x',num2cell(rand(1,1000)))

mehr als ein Jahr vor | 0

Beantwortet
Can one Function call Trigger Multiple Subsystems?
Function-Call Split https://www.mathworks.com/help/simulink/slref/functioncallsplit.html

mehr als ein Jahr vor | 0

| akzeptiert

Beantwortet
运行s-function Output argument "sys" (and possibly others) not assigned a value in the execution with "ctrl>mdlOutputs" function.
Probably a typo at the last line of this code below. Should be 'sys', not 'sym'. Also need to add a line 'end' to finish this fu...

mehr als ein Jahr vor | 1

| akzeptiert

Beantwortet
my for loop stop after the first valid number has been found how do i fix this
Use "result_1", no need to create "answer_1" numbers=1:100; result_1=[]; for i =1:numel(numbers); num=numbers(i); i...

fast 2 Jahre vor | 0

| akzeptiert

Beantwortet
hi i started the matlab onramp course and im stuck on this further practice question i wld appreciate if anyone cld help me or even give an hint
density=10:10:100 index=[1 3 6] SelectedDensityValue=density(index)

fast 2 Jahre vor | 0

Beantwortet
Questions regarding Unit Delay block initial condition and model recompilation
Use Simulink.Parameter Specify its storage class as "ImportFromFile" and specify a HeaderFile name. When the code is generated...

fast 2 Jahre vor | 0

Beantwortet
Why am I getting a computed maximum size is not bounded error in a MATLAB Function block in Simulink R2021a even when using assert?
The Simulink diagnostic is probably not designed to read the assert() function. The proper way for this is to define those data...

fast 2 Jahre vor | 0

Beantwortet
How do I use the unit per mille in Simulink parameters and ports?
It is "m" for "milli". "mille" means "a thousand", that is "k" for "kilo".

fast 2 Jahre vor | 0

Beantwortet
switching of svpwm is not working . it is not showing staircase mode in scope
To convert radians to degree, the Gain should be 180/pi. You had it as pi/180. That seems to be the cause. The logic seems corr...

fast 2 Jahre vor | 0

| akzeptiert

Beantwortet
how to write a program combininb name and age?
No Switch statement is needed. This practice is to get the input and put it in the right format. help input help sprintf

fast 2 Jahre vor | 1

Beantwortet
Is it possible to access the blocks inside the model under test from the test harness in custom criteria script of simulink test?
I think the testing harness model is using the Model block to reference the model under test, so you can't access the block dire...

fast 2 Jahre vor | 0

| akzeptiert

Beantwortet
Why do I receive "Error in port widths or dimensions"?
Simulink uses forward propagation and back propagation to determine the size of the signal. There is a conflict in this propagat...

fast 2 Jahre vor | 0

Beantwortet
How to use global variable in MATLAB discrete-event system block (not MATLAB Function Blocks)?
Use Global Variables in System Objects https://www.mathworks.com/help/simulink/ug/use-global-variables-in-system-objects.html#b...

fast 2 Jahre vor | 0

| akzeptiert

Beantwortet
How to save a MATLAB Simulink based simulaton with scopes data intact for future viewing?
Simulation Manager https://www.mathworks.com/help/simulink/slref/simulationmanager.html

fast 2 Jahre vor | 0

Beantwortet
How to save in Simulink output/results to different files
SDI datastore and tall array https://www.mathworks.com/help/simulink/slref/matlab.io.datastore.sdidatastore.html

fast 2 Jahre vor | 1

Beantwortet
I have some calcualted variable in simulink which will create an array is there a block to work this out?
https://www.mathworks.com/help/simulink/slref/selector.html

fast 2 Jahre vor | 0

Beantwortet
How can I save the text in the model workspace variable description?
mw=get_param(bdroot,'ModelWorkspace'); a=mw.getVariable('Param'); >> s=get(a,'Description') s = 'abc'

fast 2 Jahre vor | 0

| akzeptiert

Beantwortet
get Simulink block libinfo in find_system
'ReferenceBlock' is a block property. 'Library' is not. You are probably looking for 'LinkStatus'. model='f14'; open_system(mo...

fast 2 Jahre vor | 0

| akzeptiert

Beantwortet
How to adjust font size in Matlab editor
Fonts, Custom, Editor

fast 2 Jahre vor | 0

| akzeptiert

Mehr laden