Beantwortet
Error Using unitConvert from Celsius to Fahrenheit.
Try again. It seems correct to me in R2022b.

6 Monate vor | 0

Beantwortet
Associating labels to licenses
On a Windows PC, start a "cmd" window, run "vol"

6 Monate vor | 0

| akzeptiert

Beantwortet
save does not recognize text scalar
It is not about the variable name myFilename. save(myFilename) or save(myFilename,'x')

6 Monate vor | 0

| akzeptiert

Beantwortet
Call a block exactly once with Simulink Profiler
"simply divide the total time given by the Simulink Profiler by the number of calls to get the time of one call" That is a good...

6 Monate vor | 1

Beantwortet
datetime InputFormat is returning month for minutes
It is correct running your code here in R2024b. s = "2025040901:42:23 PM"; datetime(s, 'InputFormat', 'yyyyMMddhh:mm:ss a') s...

6 Monate vor | 1

| akzeptiert

Beantwortet
Can MATLAB be installed as root on Linux and used by other user accounts?
Yes. I've done that. Download the installation file and add "sudo" when running the installation command. Under the section "MA...

6 Monate vor | 0

Beantwortet
How can we obtain whether a block output remains high for say 5 milli seconds in Simulink
If you have the Simulink Test toolbox, there is a "Temporal Assessment" called "must stay true for at least" If not, you can de...

6 Monate vor | 0

Beantwortet
Why doesn’t the Simulink Editor window open automatically when I double-click a .slx file on Windows?
I tried R2022b on a Windows machine, double clicking a .slx file will open MATLAB and then the Simulink model is opened. Try re...

7 Monate vor | 0

Beantwortet
How can I save git audit info embedded into simulation output
Run system(), or use MATLAB's git command, e.g. OutStr=system('git status') help git

7 Monate vor | 0

| akzeptiert

Beantwortet
Execution order of blcks
You can set the block priority number. There are limitations. See https://www.mathworks.com/help/simulink/slref/set-priority-in...

9 Monate vor | 0

Beantwortet
Get bus elements from output port
If doing it interactively, you can hook a BusSelector block and then open the dialog If through script, you can run Simulink.da...

9 Monate vor | 1

| akzeptiert

Beantwortet
How to access parameter attributes from data dictionary in Simulink block
By default, Param.Min refers 'Param' as a structure and 'Min' as one of its field. I've tested it. You can use Simulink.data.e...

9 Monate vor | 0

Beantwortet
How to send one array element at a time to a subsystem every 0.5 seconds in Simulink?
Nothing special. Use a Counter block (free-running or limited) in combination with the model solver setting to provide the step ...

9 Monate vor | 0

| akzeptiert

Beantwortet
How to use circshift in Simulink?
It is not really a matrix. I suggest debugging the MATLAB Function first. Provide a Constant vector input, e.g. (1:5), observe t...

10 Monate vor | 0

| akzeptiert

Beantwortet
Restart signal from workspace in Simulink
Use an Integrator block and enable its "Reset" inport, which can receive your "reset" or "trigger" signal. The input to the In...

10 Monate vor | 0

| akzeptiert

Beantwortet
I need help in fixing this code as I keep getting errors
No error but warnings. The cause is that N/2 is not an integer because in your case, N is 1001. It is surprise that in the exa...

10 Monate vor | 0

Beantwortet
Matlab gave me a right value for PA< PB< PZa ,PZb, Pzc but they said the wrong thing about conclusion, they said " does not equl. However, it will equal
It is not robust to use == operator to compare two floating-point data. Search for "floating point data equal comparison" and yo...

10 Monate vor | 0

Beantwortet
Fliping Mux in Matlab code
set_param(BlockPath,'Orientation','left')

11 Monate vor | 0

| akzeptiert

Beantwortet
check Matlab tlbxs availabe and license
featureStr={'MATLAB','Simulink'} index = cellfun(@(f) license('test', f), featureStr) availableFeatures = featureStr(logical(i...

11 Monate vor | 0

Beantwortet
Branched Merge Block Check - How do I prevent this warning ?
Do you have cascaded Merge blocks? Do any of the incoming signals to Merge1 and Merge2 come from a Merge block? Or the output of...

11 Monate vor | 0

Beantwortet
Matlab function in Simulink exhibiting slow reaction time
I must know this. 1700 seconds is roughly 1/50 of the simulation time (24 hours). It is the default setting. It must mean that y...

11 Monate vor | 0

| akzeptiert

Beantwortet
How to make custom library in Simulink available to other users and in different versions?
If you have a newer version of MATLAB (e.g. R24b), you can save/export a Simulink model or library as older version (e.g. R23b),...

11 Monate vor | 0

Beantwortet
how can I array the external inputs for code generation in Simulink embedded coder?
For the array case, you just need to specify the size of that Inport block. Keep in mind that you can't comibne multiple inputs ...

11 Monate vor | 0

Beantwortet
Table.Properties.VariableNames will add ... to long Variable Names
I think the OP was referring to the three dots in the image in the header row. It is a display, @Alexander Szambor. If you drag...

11 Monate vor | 1

Beantwortet
How to call columns from table when heading names are variable dependent
use data.(MaxColumn). This is similar to dynamic field names like below. a.FirstColumn=1; ColumnName='FirstColumn' a.(ColumnN...

11 Monate vor | 0

| akzeptiert

Beantwortet
I am getting error for configurable subsystem in R2024b
"Configurable subsystem" is in pretty old versions of Simulink. It sounds like that in R2024b, it is definitely no longer suppor...

11 Monate vor | 1

Beantwortet
How to read out value from simout object
You need to click that signal line, right click, select properties, and then give it a name and log the signal. Once done that, ...

11 Monate vor | 0

| akzeptiert

Beantwortet
Delay - bus as initial condition and bus propagation
I am intested in this question so I made an example. According to the document, 'The initial condition x0 port accepts nonvirtu...

11 Monate vor | 0

Beantwortet
Simulation manager with initFcn
'InitFcn' is executed before the simulation starts, that is probably the reason that your parameter values set in the multiple s...

11 Monate vor | 0

Beantwortet
What is the Matlab code that connects a variable to a Slider Switch Block?
The 'binding' needs to be a block in the model. If that block uses 'A' as a parameter and that parameter is selected to be bound...

11 Monate vor | 1

Mehr laden