Bidirectional 2-level AC-DC Converter Average Model
This is an average AC-DC VSC. This model will show you the fundamental of VSC about d/q decoupling. The control system operates in pu, so it is flexible to apply this in another network just after changing the ratings in the "Mask" of the converter block. If you want to build a real model based on this average model, you can enable PMW, and replace the controlled 3 voltage sources with 6 switches.
If you have any questions or suggestions, please contact me, chunpeng.li@strath.ac.uk.
Notes:
1. Inside the converter control parts, all parameters adopt per unit.
2. Open the "Mask" of the converter [Ctrl+M], go to "Initialisation" tab, you can change all ratings.
3. Double click the converter, in the "global monitor" block, you can observe the variables in pu. And in the up-left boxes, red blocks, you can switch and tune the P/V control, and adjust Q setpoint.
Zitieren als
Chunpeng LI (2024). Bidirectional 2-level AC-DC Converter Average Model (https://www.mathworks.com/matlabcentral/fileexchange/69948-bidirectional-2-level-ac-dc-converter-average-model), MATLAB Central File Exchange. Abgerufen .
Li, Chunpeng, et al. “Metrology Requirements of State-of-the-Art Protection Schemes for {DC} Microgrids.” The Journal of Engineering, vol. 2018, no. 15, Institution of Engineering and Technology ({IET}), Oct. 2018, pp. 987–992, doi:10.1049/joe.2018.0254.
Kompatibilität der MATLAB-Version
Plattform-Kompatibilität
Windows macOS LinuxKategorien
Tags
Quellenangaben
Inspiriert von: DC Microgrid Demo
Communitys
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!Live Editor erkunden
Erstellen Sie Skripte mit Code, Ausgabe und formatiertem Text in einem einzigen ausführbaren Dokument.
Version | Veröffentlicht | Versionshinweise | |
---|---|---|---|
1.1.0 | Fix a mistake. The 3 phase measurement should measure phase-ground rather than phase-phase voltage. |
||
1.0.0 |