stateflow

3 Ansichten (letzte 30 Tage)
Murali Mohan
Murali Mohan am 15 Jun. 2011
Hi all, Here I am using "after(0.025, sec)" in statechart for generating pulse, but when it wached on scope,its generating at 0.03, why is the difference. Can any help me how to make exact at 0.025.
  3 Kommentare
Arnaud Miege
Arnaud Miege am 15 Jun. 2011
Also, how often does your chart update?
Murali Mohan
Murali Mohan am 17 Jun. 2011
sample time provided for the model is 0.01

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

Gerd
Gerd am 17 Jun. 2011
Hi Murali,
using a sample time of 0.01s for your model lets you only generate pulses with a multiple of the basic sample time(0.01 / 0.02 / 0.03) If you want to generate a pulse of 0.025 you have to increase your sample time to e.g. 0.001s
Gerd
  3 Kommentare
Gerd
Gerd am 17 Jun. 2011
Murali,
please open the model.
Double click on the upper chart "With absolute Time".
Change the transition to "After(0.025,sec)".
Hit Ctrl+E. Change the fundamental sample time to 0.001.
Open the scope and open Parameter pane. Go to "History".
Deselect Limit data points to last.
Run the model and observe the result.
I did these steps and the result is Ok
Murali Mohan
Murali Mohan am 17 Jun. 2011
Thanks Gerd for your reply :)