Dealing with multiple signal selection
5 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hi,
I am trying to use simulink to test multiple actuators depending on the type of control, longitudinal, collective, lateral etc.. I have my simulink model set up where I can make the actuator type selection via GUI to feed my simulink model the parameters for a longitudinal, collective, lateral control etc.
I am at the point where I want to use the signal generator to test various performance requirements specific to each actuator. Is there a way I can select which index signal I want run without simulink generating all the signals in the signal generator? I have tried doing this manually using a multichannel switch, but the run time is slow because simulink calculates the signals even if they are unused.. So what I am looking for is the most efficient way that can be interfaced with GUI.
0 Kommentare
Antworten (4)
Ryan G
am 25 Sep. 2012
See the first example in the this blog post. Wrap the generators in enabled subsystems and they will only be run when they are enabled.
0 Kommentare
Azzi Abdelmalek
am 25 Sep. 2012
Bearbeitet: Azzi Abdelmalek
am 26 Sep. 2012
try switch case action subsystem block or if action subsystem block
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/172072/image.jpeg)
0 Kommentare
Michael
am 25 Sep. 2012
1 Kommentar
Azzi Abdelmalek
am 26 Sep. 2012
look at the above figure, place in each if action subsystem your generator
Michael
am 26 Sep. 2012
1 Kommentar
Azzi Abdelmalek
am 26 Sep. 2012
Michael, don't reply to a comment with an answer, just click on comment this answer.
I want to know, how many differents signals are you using? what kind of signals? Is a signal builder necessery?
Siehe auch
Produkte
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!