Audio compression using DCT - but i get same size of files after inverse DCT

7 Ansichten (letzte 30 Tage)
Hi I have a file ( 1.wav) - I'm trying to compress the first two seconds for this audio by using Discrete cosine transform . I attached the code , but when i use the command ( whos ) for the original samples and reconstructed samples after inverse DCT i get the same size and number of bytes So any explanation , and how i get the compression ratio ?

Akzeptierte Antwort

Walter Roberson
Walter Roberson am 4 Mai 2018
Bearbeitet: Walter Roberson am 4 Mai 2018
That is expected. You are writing out the re-expanded data as samples. There will be the same number of samples as before, so it is going to take the same output size (probably.)
See also my recent discussion at https://www.mathworks.com/matlabcentral/answers/398289-how-can-i-do-audio-compression-using-huffman-encoding#comment_563731 . For DCT you would not need to write out a dictionary, but you would not write out the coefficients you had zeroed out. You would, however, need to write out the original number of coefficients so when you read the values in, you knew how many zeros to pad with before reconstruction.
  28 Kommentare
Abid Ali
Abid Ali am 30 Apr. 2020
How to read back comp binary file to decode it

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (1)

Abid Ali
Abid Ali am 30 Apr. 2020
How to read back the comp binary file, please Help me!!
Thanks

Kategorien

Mehr zu Denoising and Compression finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by