I have a transfer function with order three in both numerator and denominator. I am tuning the block using the control system tuner to find the best coefficients for the block for a desired function. My question is how to tell the tuner that the coefficients to be found must be positive values?
ex: tf=(a1*s+1)(a2*s+1)(a3*s+1)/((b1*s+1)(b2*s+1)(b3*s+1))
I want to find the values of the parameters all a & b to be positive values. Any idea? Thanks

Antworten (1)

Sebastian Castro
Sebastian Castro am 17 Apr. 2017
For all tuned blocks, you can expand the variable name and set their "Minimum" and "Maximum" values. If you set a minimum of 0, does it work?
Sebastian
  3 Kommentare
Ismaeel
Ismaeel am 18 Apr. 2017
Bearbeitet: Ismaeel am 18 Apr. 2017
Apparently, there is a technical issue to upload the picture. Anyway, this is what I got:
Numerator coefficients:
[-0.17873835660206 -0.241501688056885]
Denominator coefficients:
[1 0.372855801788186]
Ismaeel
Ismaeel am 18 Apr. 2017
Bearbeitet: Ismaeel am 18 Apr. 2017
I have soled my problem by changing the transfer function to multiple simple blocks (integral, gain, and sum) using the rules from control theory. Thanks Castro.