Hi, everyone,
I have a question regarding the SPS block "Synchronous Machine pu fundamental". I opened the block (configured in continuous) to visualize the equations and write the model of the equations in per unit system and I found a gain called SM.N that multiplies the field voltage (Vfd).
Could you help me to understand the addition of this gain and could you share resources to understand the per-unit system that it is using.
I add a screenschot.
Thank you

 Akzeptierte Antwort

praguna manvi
praguna manvi am 13 Feb. 2025
Bearbeitet: praguna manvi am 15 Apr. 2025

0 Stimmen

You can refer to the documentation for the "Synchronous Machine pu Fundamental," which mentions that the "Vf" input is normalized with respect to the nominal field voltage so that a 1 pu input produces a 1 pu stator voltage at no load. This is why there is a "Gain Block." Here is the link to the documentation:
Additionally, for more information on the "pu units system", refer to the following link:
Hope this helps!