How to resolve - An error occurred ('Simulink:modelReference:TargetUpdateError') when calling 'sim':
36 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
When I'm doing SIL testing for a controller model, I get these errors. Help me resolving these errors.
An error occurred ('Simulink:modelReference:TargetUpdateError') when calling 'sim':
Block 'pidctrl/Subsystem/Transfer Fcn' uses continuous time, which is not supported with the current configuration
0 Kommentare
Antworten (1)
Keshav
am 22 Aug. 2023
Hi Mahendran,
I understand that you are encountering an error during SIL testing for a controller model.
The error message,
"An error occurred ('Simulink:modelReference:TargetUpdateError') when calling 'sim': Block 'pidctrl/Subsystem/Transfer Fcn' uses continuous time, which is not supported with the current configuration"
indicates a compatibility issue with a block in your controller model. Specifically, the block “pidctrl/Subsystem/Transfer Fcn”
is using continuous time, which is not supported in the current configuration.
To resolve this error, verify the configuration settings of the “Transfer Fcn” block within the “pidctrl/Subsystem”. Make sure that the block is set to use a discrete-time implementation instead of continuous time.
You can check the sample times in your model to see which ones are continuous and need to be adjusted. To learn how to display the sample time in your model, you can refer to the below MathWorks documentation.
I hope this information helps!