Z transfer fcn under simulink and cmd line

1 Ansicht (letzte 30 Tage)
Bruce
Bruce am 5 Apr. 2023
Kommentiert: Jon am 6 Apr. 2023
I create a simple cmd from S to Z domain as below, and the result is matched with my understanding;
clear
rth1=0.0268;
tau1=1066.6;
Ts=0.05;
tf1=tf(rth1,[tau1 1])
dtf1=c2d(tf1,Ts)
figure;
step(tf1);
figure
step(dtf1);
but when i create this under simulink, the result is not matched, as you can see the Z transfer fcn output is quite different with the S transfer fcn.
Is there anyone can help me?
  2 Kommentare
Jon
Jon am 5 Apr. 2023
Please attach you Simulink model and any scripts or other functions needed to run your example - thanks
Jon
Jon am 5 Apr. 2023
Please see my answer below, I was able to work out what the issue was without your code, so no need to attach it now

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

Jon
Jon am 5 Apr. 2023
This appears to be due to a round off error in the denominator of the discrete transfer function input to Simulink.
Try for example with the denominator set to
[1 -0.999949]
instead of
[1 -1]
and you will see that the step response of the continuous and discrete approximation are now much closer
  5 Kommentare
Bruce
Bruce am 6 Apr. 2023
Thanks a lot, Jon. Your answer and explaination is quite clear, thanks again!
Jon
Jon am 6 Apr. 2023
Your welcome, it was an interesting problem

Melden Sie sich an, um zu kommentieren.