Simulink coder and disabled subsystems

I'm trying to generate code from a Simulink diagram which contains an enabled subsystem. The enable is tied to a workspace variable that is always 0 (the subsystem should never be enabled). Still, it seems that the coder tries to generate code from this system. Why is this happening? Can I stop it from happening?
Thanks

Antworten (2)

Paolo
Paolo am 7 Apr. 2015

0 Stimmen

I have the same problem. It seems that the optimization "Simulation and code generation -> Block reduction" doesn't properly work in this case.
TAB
TAB am 7 Apr. 2015

0 Stimmen

Check if
Optimization > Inline Parameters
option is selected.
If this option is not selected, then Simulink will assume every parameter as tunable and it will be included in code independent of its value.

Kategorien

Mehr zu Simulink Coder finden Sie in Hilfe-Center und File Exchange

Gefragt:

am 21 Jan. 2015

Beantwortet:

TAB
am 7 Apr. 2015

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by