How can i fix this error in the Impulse Response Measurer?

3 Ansichten (letzte 30 Tage)
Hi,
since today i have the problem that i get the following error message in the "impulse response measurer" (see picture) and actually no data is recorded.
I haven't found a workaround for this yet. Has something similar already happened to someone ?
Thanks in advance!

Akzeptierte Antwort

Jimmy Lapierre
Jimmy Lapierre am 19 Jan. 2022
Hi Mehmet, could you try increasing the “Duration per run” relative to the “sweep duration”. The sweep methods requires this period of silence after the sweep to record the response.
It appears you found a case where the error message is of no help, we will fix that.
  2 Kommentare
Mehmet Cibir
Mehmet Cibir am 21 Jan. 2022
Hi Jimmy,
thank you for your response!
It seems that increasing the "Duration per run" relativ to the "sweep duration" solves the issue.
I have tried it with different settings and have so far got no new error message.
Jimmy Lapierre
Jimmy Lapierre am 21 Jan. 2022
Great to hear! We'll improve that error message nevertheless.

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Kategorien

Mehr zu Measurements and Spatial Audio finden Sie in Help Center und File Exchange

Produkte


Version

R2021b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by