I want to give a digital output to my DAQ using Simulink. But I get an error says:Input to a block must have a discrete sample time.
Ältere Kommentare anzeigen
I am using Data Acquisition Toolbox. I want to give a digital output from my Data Translation DAQ (DT9812-10v) by using simulink.

I used the Digital Output block from the toolbox and I connect it with a Constant block as an input. When I run the program, it gives me error message: Error reported by S-function 'sdaqdo' in 'research_projek_1/Digital Output': Input to a block must have a discrete sample time.
How would I overcome this problem? Thank you

Akzeptierte Antwort
Weitere Antworten (0)
Kategorien
Mehr zu Communications Toolbox finden Sie in Hilfe-Center und File Exchange
Produkte
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!
