Back-to-Back Test Status Distribution for Normal and SIL Mode
Metric ID
slcomp.sil.B2BTestStatusDistribution
Description
The back-to-back testing metrics perform translation validation between a model and the generated code.
This metric returns the distribution of back-to-back testing statuses for each test by comparing, at each time step, the outputs of the model simulation and the outputs of the code executed in software-in-the-loop (SIL) mode. The metric compares the normal mode and SIL mode test runs from baseline, equivalence, and simulation tests.
Supported Artifacts
You can collect this metric for the Units in your project. To control what the dashboard classifies as a unit, see Categorize Models in Hierarchy as Components or Units.
Computation Details
For information on how the metric calculates the back-to-back testing statuses, see Back-to-Back Test Status for Normal and SIL Mode.
Collection
To collect data for this metric, execute the metric engine and use getMetrics
with the metric
ID
slcomp.sil.B2BTestStatusDistribution
.
metric_engine = metric.Engine; execute(metric_engine,"slcomp.sil.B2BTestStatusDistribution"); results = getMetrics(metric_engine,"slcomp.sil.B2BTestStatusDistribution")
Collecting data for this metric loads the model file and test result files and requires a Simulink® Test™ license.
Results
For this metric, the function getMetrics
returns a
metric.Result
instance for each unit in the project.
Instances of metric.Result
return
Value
as a distribution structure that contains these fields:
BinCounts
— The number of failed, passed, and untested tests, returned as a vector that contains these elements:BinCounts(1)
— Number of tests that failed back-to-back testingBinCounts(2)
— Number of tests that passed back-to-back testingBinCounts(3)
— Number of tests that are untested for back-to-back testing
For example, if one test fails, two tests pass, and three tests are untested,
BinCounts
returns[1;2;3]
.BinEdges
— The possible back-to-back testing statuses, returned as a vector:0
— Test failed back-to-back testing1
— Test passed back-to-back testing2
— Test is untested for back-to-back testing
OverallCount
— The total number of tests. The metric calculatesOverallCount
as the sum of the values inBinCounts
.Ratios
— The percentage, in decimal form, of tests with a given status, returned as a vector that contains these elements:Ratios(1)
— Percentage of tests that failed back-to-back testingRatios(2)
— Percentage of tests that passed back-to-back testingRatios(3)
— Percentage of tests that are untested for back-to-back testing
For example, if 0% of the tests failed, 10% of the tests passed, and 90% of the tests are untested,
Ratios
returns a vector with the percentages in decimal form:[0;0.1000;0.9000]
.
Compliance Thresholds
The default compliance thresholds for this metric are:
Compliant
— 100% of tests in the unit passedNon-Compliant
— One or more tests failed or are untestedWarning
— None
See Also