ssGetParameterTuningCompliance
Get the sample time behavior and tunability for S-function blocks with port-based sample times
Syntax
logical ssGetParameterTuningCompliance(SimStruct *S)
Arguments
- S
- SimStruct that represents an S-function block. 
Description
Use this macro to specify sample time behavior for your S-function with port-based
                sample times. If this method returns False, the Simulink® engine does not allow a sample time of Inf for this
                S-function. If this method returns True, the S-function block is
                tunable and its ports can have a sample time of Inf. To set the
                sample time for ports in the S-function, use ssSetOutputPortSampleTime and
                    ssSetInputPortSampleTime. These
                ports execute every time you tune any parameter in your model during
                simulation.
Languages
C, C++
See Also
Version History
Introduced in R2015b