ssGetParameterTuningCompliance
Get the sample time behavior and tunability for S-function blocks with port-based sample times
Syntax
logical ssGetParameterTuningCompliance(SimStruct *S)
Arguments
S
SimStruct that represents an S-function block.
Description
Use this macro to specify sample time behavior for your S-function with port-based
sample times. If this method returns False
, the Simulink® engine does not allow a sample time of Inf
for this
S-function. If this method returns True
, the S-function block is
tunable and its ports can have a sample time of Inf
. To set the
sample time for ports in the S-function, use ssSetOutputPortSampleTime
and
ssSetInputPortSampleTime
. These
ports execute every time you tune any parameter in your model during
simulation.
Languages
C, C++
See Also
Version History
Introduced in R2015b